Control Panel with T104M201 & T104M Mechanisms
Model#T12404R
- Proposition 65 warning for California residents
Control Panel with T104M201 & T104M Mechanisms
Model#T12404R
- Proposition 65 warning for California residents
- Available with one or two heavy-duty time switch mechanisms
- Accepts any combination of PF1000M, P1403ME, P1353ME, P4043ME, P4243ME, T100M or RC2000M Series mechanisms
- Load center dead front has two knockouts for switches or GFCIs and one on the side
- Wiring devices may be installed in these load centers with the use of Standoffs, sold separately below
- Control two-speed pumps with the T10604R
- Distribution/Control Panel
- Motor Control
- Pump Control
Switch Type DPST CA Prop 65 Message Please see the Warning @ www.P65Warnings.ca.gov California Proposition 65 Lead Color Beige Country of Origin (Intermatic) MEXICO CSA Certification cCSAus Enclosure Type 3R Beige metal Heater Protection Switch Yes Inductive 40 A, 120 VAC, 60 Hz, 40 A, 208 VAC, 60 Hz, 40 A, 240 VAC, 60 Hz Inductive Load Ratings Ranges 40 A, 120-240 VAC, 60 Hz Input Voltage Range(s) 208-277 VAC, 60 Hz Knockout Dimensions Back (1) combination 1/2" - 3/4" and (1) 3/4" - 1" Knockout Dimensions Bottom (5) combination 1/2" - 3/4" and (2) combination 3/4" - 1" Knockout Dimensions Left (1) combination 1/2" - 3/4" Knockout Dimensions Right (1) 1 3/4" x 2 3/4" Material Metal Maximum Power Consumption (W) 3 W Mechanism Supply Voltage 240/240 VAC, 60 Hz Mechanisms T104M201 & T104M Motor Load Ratings Ranges 2 HP, 24 FLA @ 120 VAC, 60 Hz; 5 HP, 28 FLA @ 240 VAC, 60 Hz Number Of Circuits 2 Number of Trippers Included 2 ON/2 OFF Other Certifications and Compatibilities Green Energy Pilot Duty (NO) 1000 VA, 120 VAC, 60 Hz, 1000 VA, 208 VAC, 60 Hz, 1000 VA, 240 VAC, 60 Hz Pilot Duty Load Ratings Ranges 1000 VA, 120-240 VAC, 60 Hz Resistive 40 A, 120 VAC, 60 Hz, 40 A, 208 VAC, 60 Hz, 40 A, 240 VAC, 60 Hz Resistive Load Ratings Ranges 40 A, 120-240 VAC, 60 Hz RoHS Certification X Tungsten (NO) 40 A, 120 VAC, 60 Hz, 40 A, 208 VAC, 60 Hz, 40 A, 240 VAC, 60 Hz Tungsten Range(s) 40 A, 120-240 VAC, 60 Hz Warranty Period 1-Year limited Operating Temperature Max (°C) 54 Operating Temperature Max (°F) 130 Operating Temperature Min (°C) -40 Operating Temperature Min (°F) -40 Product Depth (in) 4.75 Product Depth (mm) 120.7 Product Height (in) 12.875 Product Height (mm) 327 Product Width (in) 10.875 Product Width (mm) 276.2 Unit Carton Height (in) 5.63 Unit Carton Length (in) 13.81 Unit Carton Weight (lb) 11.227 Unit Carton Width (in) 12.06 Units Per Pallet 63